Description

The ENFORCER 4-output Access Power Controller Board centralizes the power sources and gives individual control for various access control locking devices, such as electromagnetic locks, electric shear locks, door strikes, deadbolt locks, and more. Each output is individually controllable, individually fused, and with individual status LEDs. Each output can operate in failsafe or fail-secure modes. Each board includes wet and dry trigger inputs for emergency activation and includes power failure supervision relays and auxiliary supervision relays.

  • For 12/24 VAC/VDC operation
  • Each output individually fused
  • Each output can operate in both fail-safe and fail-secure modes
  • Each output individually controlled
  • Individual output relays (10A@24VDC)
  • Output fuses rated at 3.0A (PTC@2.5A)
  • Individual status LEDs for each output and for emergency input
  • Auxiliary supervision relay (1A@28VDC)
  • Equipped with dry and wet trigger inputs
  • Includes auxiliary interface to enable emergency egress, alarm monitoring, or to trigger other devices
  • Includes auxiliary interface disconnect, individually selectable for each output
  • Compatible with ENFORCER Access Control Power Supplies

 

Specifications

Input voltage 12/24 VAC/VDC
Input current draw 10A@24VAC
Number of outputs 4
Output fuse type/rating Blade 3.0A
Output relays Form C (10A@12VDC)
Auxiliary interface output DPDT (1A@28VDC)
LED – Status 4 (red, on when relay is energized)
LED – Auxiliary Interface 1 (green on when auxiliary input is triggered, alarm condition)
Operating humidity 0~95%
Operating temperature -40°~167° F (-40°~75° C)
Dimensions 5-3/8″x3-5/8″x15/16″ (136x92x23 mm)
Weight 4.8-oz (137g)

 

Troubleshooting

No DC output
  •  Check whether the AC input voltage or backup battery voltage is normal
Low DC voltage output
  • Check whether the output voltage setting is correct
  • Check whether the AC input wattage is correct (see chart, pg. 3)
  • If the battery is supplying power, check whether the battery voltage
    is normal
  • Check whether the power supply board is overloaded
No backup battery power
  • Check whether the battery voltage is normal or already discharged
  • Check whether the master fuse has burned out

Why buy Certified?

Certified Alarm Distributors - Top USA Reseller Certified Alarm Distributors - Your team of experts Certified Alarm Distributors - Easy 30 day returns
Top USA Reseller
Trusted since 1976
Your Team of Experts
Pro Help when you need it
Easy 30 Day Returns
Satisfied or refunded

Secure Checkout With

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like

Recently viewed